Product overview

Product model: 900X
Nominal diameter: DN40~1600mm
Nominal pressure: PN1.0~2.5MPa
Applicable medium: water, oil, sea water, sewage
Applicable temperature: 0~80℃
Structure length standard: GB/T12221-2005
Standard of connection flange: GB/T9113
Pressure and temperature grade: GB/T12224-2005
Test inspection standard: GB/T13927-2008

900X Emergency Shut Off Valve product details

Hydraulic control valve is a hydraulic control valve, hydraulic control valve is a main valve and attached to the catheter, pilot valve, needle valve, ball valve, pressure reducing valve, slow closing check valve, flow control valve, pressure relief valve, Hydraulic electric control valve, pump control valve. Before the hydraulic control valve to be installed filters, and should facilitate the sewage requirements.

900X emergency shut-off valve is used for fire water and domestic water in parallel with the water supply system, used to deploy the water supply direction of the valve. When the fire broke out, the fire was in urgent need of a lot of water, immediately cut off the domestic water, to ensure adequate fire water; when the fire water pressure to stop reducing, the valve automatically opens, was normally open to resume living water supply. The valve so that the system does not require a separate fire special water supply pipe network, greatly reducing construction costs and water consumption. Valve control of high sensitivity, safe, reliable, easy commissioning, long service life.


900X Emergency Shut Off Valve structural features and uses

Emergency shut-off valve for domestic water supply and fire water supply Parallel water supply system, the normal situation for domestic water, fire water when the fire occurs, the valve automatically turn off domestic water to ensure adequate fire fighting water. When the fire stopped reducing the pressure of water, the valve automatically restore domestic water, the valve eliminates the need for separate fire special water supply pipe network, which greatly saves construction costs and daily water consumption. The valve control sensitive, safe, reliable, simple commissioning, long service life.


900X Emergency Shut Off Valve main technical parameters

Nominal pressure (Mpa)

Shell test pressure (MPa)

Seal test pressure (MPa)

Suitable media

Medium temperature (℃)

1.0

1.5

1.1

water

0-80

1.6

2.4

1.76

2.5

3.75

2.75


900X Emergency Shut Off Valve main parts material

Part Name

Parts and materials

Body valve cover

WCB

Valve seat disc

Copper alloy

O-ring seals

Nitrile rubber

Valve stem

2Cr13

spring

50CrVA

Needle valve

Copper alloy

Ball valve

Copper alloy

Float valve

Copper alloy

Micro filter

stainless steel


900X Emergency Shut Off Valve connection size


DN

L

A

A1

H

H1

F


       mm

D1 
       mm

D2 
       mm

n-Φd

mm

mm

mm

mm

mm

mm

PN1.0

PN1.6

PN2.5

PN1.0

PN1.6

PN2.5

PN1.0

PN1.6

PN2.5

PN1.0

PN1.6

PN2.5

20

180

292

136

342

247

116

105

105

105

75

75

75

58

58

56

4-13.5

4-13.5

4-14

25

201

292

136

342

247

116

115

115

115

85

85

85

68

68

65

4-13.5

4-13.5

4-14

32

180

292

136

342

247

116

140

140

140

100

100

100

78

78

76

4-17.5

4-17.5

4-18

40

205

330

155

395

278

170

150

150

150

110

110

112

88

88

84

4-17.5

4-17.5

4-18

50

205

330

155

395

278

170

165

165

165

125

125

125

102

102

99

4-17.5

4-17.5

4-18

65

250

350

165

405

298

180

185

185

185

145

145

145

122

122

118

4-17.5

4-17.5

8-18

80

250

365

175

430

313

210

200

200

200

160

160

160

133

133

132

8-17.5

8-17.5

8-18

100

320

410

195

510

350

275

220

220

235

180

180

190

158

158

156

8-17.5

8-17.5

8-22

125

415

455

220

560

365

310

250

250

270

210

210

220

184

184

184

8-17.5

8-17.5

8-26

150

415

475

230

585

420

355

285

285

300

240

240

250

212

212

211

8-22

8-22

8-26

200

500

530

255

675

450

460

340

340

360

295

295

310

268

268

274

8-22

12-22

12-26

250

605

623

300

730

470

500

395

405

425

350

355

370

320

320

330

12-22

12-26

12-30

300

725

700

340

760

490

580

445

460

485

400

410

430

370

370

389

12-22

12-26

16-30

350

787

840

415

840

526

640

505

520

555

460

470

490

430

430

448

16-22

16-26

16-33

400

787

880

430

910

570

715

565

580

620

515

525

550

482

482

503

16-26

16-30

16-36

450

864

930

460

1030

610

780

615

640

670

565

585

600

532

550

548

20-26

20-30

20-36

500

914

980

490

1135

665

830

670

715

730

620

650

660

585

585

609

20-26

20-33

20-36

600

1067

1060

530

1270

725

920

780

840

845

725

770

770

685

685

720

20-30

20-36

20-39

700

1650

1130

560

1460

865

980

895

910

960

840

840

875

800

800

820

24-30

24-36

24-42

800

1750

1230

610

1640

975

1050

1015

1025

1085

950

950

990

905

905

928

24-33

24-39

24-48



Reminder:

All text, data and pictures in this article are for reference only.To see more details of the 900X Emergency Shut Off Valve performance parameters, structural dimension parameters, pricing, etc., or to request high quality printing samples, please Contact us.

+86-021-57278881
qrCode
主站蜘蛛池模板: 免费看国产曰批40分钟| 亚洲成av人片在线观看天堂无| 国产精品h片在线播放| 国产成人精品亚洲777人妖| 国产精品好好热av在线观看| 强奷乱码中文字幕| 一本大道无码日韩精品影视丶| 白嫩少妇bbw撒尿视频| 毛片一区二区三区无码| 人人妻人人澡人人爽精品日本| 久久香蕉国产线看观看怡红院妓院| 亚洲精品尤物av在线观看不卡| 亚洲熟女乱色综合亚洲小说| 亚洲妇女无套内射精| 人妻精品久久久久中文字幕69 | 亚洲 欧洲 无码 在线观看| 精品人妻系列无码专区久久 | 人妻无码人妻有码中文字幕在线| 未满十八18勿进黄网站 | 夜鲁鲁鲁夜夜综合视频欧美| 国产精品特级毛片一区二区| 免费人成网站视频在线观看国内| 久久久久人妻一区精品色| 强开小婷嫩苞又嫩又紧视频韩国| 看国产一毛片在线看手机看| 女人高潮内射99精品| 男男车车的车车网站w98免费| 国产精品亚洲专区无码牛牛 | 日亚韩在线无码一区二区三区| 亚洲日韩久热中文字幕| 欧美品无码一区二区三区在线蜜桃 | 国产自在自线午夜精品| 精精国产xxxx视频在线| 精品少妇ay一区二区三区| 国产精品未满十八禁止观看| 久久综合婷婷成人网站| 中文字幕日韩精品一区二区三区| 996久久国产精品线观看| 国产精品制服| 小雪尝禁果又粗又大的视频| 久久精品国产曰本波多野结衣 |